Enterprise Customers: Enterprise customers can set standard tolerances across their projects through the Company Tolerance page under Settings on the Siteaware platform.
Every element that Siteaware inspects is judged against a pre-defined tolerance. These tolerances are established during the project kickoff, and project teams can adjust these values to their needs by contacting their CXM.
Below is a table of Siteaware's recommended tolerances by element type. For a full list of possible tolerances per element, review the Project Tolerances page under Settings on the Siteaware platform.
Note: The minimum achievable tolerance is 1/4", but this requires that drawings be provided in CAD format and the use of a total station for measuring the GCPs.
Trade | Element | Recommended Tolerance (Imperial) | Recommended Tolerance (Metric) |
Concrete/Steel | Beams | 1" | 30mm |
Columns | 1" | 30mm | |
Core Walls | 1" | 30mm | |
Deck Forms | 1" | 30mm | |
Footings | 2" | 60mm | |
Grade Beams - Load Bearing | 2" | 60mm | |
Grade Beams- Non-Load Bearing | 12" | 300mm | |
Hold Downs | 1" | 30mm | |
Openings | 1" | 30mm | |
Piles | 3" | 100mm | |
Slab Edge | 1" | 30mm | |
Embeds | Anchor Bolts | 1" | 30mm |
CIP Embeds | 1" | 30mm | |
MEPF | Chases | 1" | 30mm |
Sleeves | 1" | 30mm | |
Hangers | 1" | 30mm | |
Floor Drains | 3" | 100mm | |
Electrical Boxes | 1" | 30mm | |
Conduit | 1" | 30mm |